
Give it the column coordinates and the site data. In under 15 minutes the pipeline returns a fully checked, code-compliant Eurocode scheme — 3D frame analysis, EC2/EC8 member design, EC7 foundations, 18 A3 drawing sheets and quantities — with every check, clause and utilisation shown. Built for preliminary design and feasibility studies, where the answer you need is “will this scheme work, and what will it take?” — not weeks of manual iteration. Independent audit gates re-verify the analysis and every member, returning PASS or FAIL before any drawing or foundation is produced: an audit is a gate, not a comment. Preliminary design only — a professional engineer must independently check and sign off the output before it is issued for construction.
A preliminary Eurocode structural scheme, drawings and quantity take-off in under 15 minutes.
One subscription, monthly or annual, unlocks every BESPA application. 7 days free, cancel any time. The demo on this page is free to try.
Stiffness model from your coordinates: gravity, wind to EN 1991-1-4 and modal response-spectrum seismic to EN 1998-1, with cracked stiffness and a rigid diaphragm.
Beams, columns, two-way slabs, ductile core walls with boundary elements, coupling beams and balconies — failing members are resized and the frame re-analysed until it converges.
Separate auditors re-check the analysis and every member against EC2, EC8 and EC7 and return PASS or FAIL. They perform no design, so they have nothing to defend.
Pads, rafts or bored piles chosen from your borehole data — a shallow solution is overruled when consolidation settlement demands piles.
Every check states demand, capacity, units, utilisation and the Eurocode clause. Governing load case shown, and gaps in the data are reported rather than silently defaulted.
Concrete volume, reinforcement tonnage and kg/m³ per element and in total — derived from the design, not measured off a drawing.
A real stiffness-matrix (FE) solution to a single/multiple-bay building frame — sway, joint and base moments, then member design. The full module runs a whole 3D building frame of up to 12 storeys (or 55 m maximum height). The preview below solves one bay of one storey of that same model.
Indicative sample — a simplified calculator, not the module. The module runs on your own data, and the figures and standards it applies are the ones you enter.
Each stage is a separate engine. Every stage writes a machine-readable export the next one reads — and that you can read too.
Gravity, wind and modal response-spectrum seismic with cracked stiffness.
Equilibrium, modal mass, drift and P-Δ reported against code limits, not assumed.
Beams, columns, slabs, core walls, coupling beams and balconies, iterated to convergence.
PASS or FAIL. No drawings or foundations are produced for a non-compliant frame.
Framing plans, beam, column and joint details, core, stairs, balconies, BS 8666 schedule.
Pads, rafts or bored piles from borehole and consolidation data.
Bearing, settlement, pile capacity and spacing, cap geometry, sliding and uplift.
Foundation GA and setting-out, pile-cap details, typical pile with strata, bar schedule.
The audit is a gate, not a comment. If the superstructure does not comply, drawings and foundation design are not produced. Every failing check is listed with its clause, its utilisation and the specific remedy.
Professional responsibility. Bespa Expert Systems output is preliminary design intended for feasibility studies and scheme development. It is not a substitute for a chartered or licensed engineer's independent checking, and a professional engineer must verify and sign off all output before it is issued for construction. Eurocode National Annex parameters vary by country — the supported annex is stated on every report.
Write to Dr. Kwasi Osafo Ampadu, or use the feedback form on the home page.
Emailinfo@bespa.online